Drive Fault (Error Code #) 215
User Guide v 2.3 — September 2015 UltraSync-E, If Equipped
Fault
Number
Fault Solution
1 Watchdog error Internal error. Cycle power to the drive.
2 Incorrect interrupt has occurred Internal error. Cycle power to the drive.
3 NMI interrupt/bus error Internal error. Cycle power to the drive.
16 Errors while booting Internal error. Cycle power to the drive.
17 Software error Internal error. Cycle power to the drive.
18 Time slot configuration Internal error. Cycle power to the drive.
19 Time slot – time error Internal error. Cycle power to the drive.
20 No free memory Internal error. Cycle power to the drive.
21 Invalid error code Internal error. Cycle power to the drive.
22 Invalid warning code Internal error. Cycle power to the drive.
23 False FPGA version Contact Husky Service.
48 Error in module A Cycle power to the drive, check wiring to
module, replace module.
50 Error in module C Cycle power to the drive, check wiring to
module, replace module.
51 Error in module D Cycle power to the drive, check wiring to
module, replace module.
53 Error in module G Cycle power to the drive, check wiring to
module, replace module.
54 Error in module H Check that module switch is in the down
position, cycle power to the drive, contact
Husky Service.
64 Mains failure Check fuses/circuit breaker, restore main power
to the drive.
65 Phase failure Check fuses/circuit breaker, restore main power
to the drive.
66 Mains under voltage Check power wiring. Measure voltage at the
drive, Phase to Phase must be greater than
208 V, correct low voltage condition.
67 Mains over voltage Check power wiring. Measure voltage at the
drive, Phase to Phase must be less than 415 V,
correct low voltage condition.
68 Under voltage 24 V Check DC power supply G1 wiring. Measure DC
voltage, must be between 20.4 V to 28.8 V, and