This command fails if one or more of the volumes in the Consistency Group is a
slave of a synchronous mirroring, and it is currently inconsistent due to either a
re-synchronization or an initialization process.
Mirroring limitations:
v This command fails if the volume is a slave of an asynchronous mirroring
coupling (either synchronous or asynchronous).
v This command fails if the volume is a slave of an inconsistent synchronous
coupling.
Example:
cg_snapshots_create cg=DBgroup snap_group=DBbackupdaily
Output:
Command completed successfully.
Access Control:
User Category Permission Condition
Storage administrator Allowed N/A
Storage integration administrator Allowed N/A
Application administrator Conditionally Allowed At least one of the volumes in
the group is mapped to a host or
cluster associated with the user.
If a Snapshot Group overwrite is
used, then the target Snapshot
Group must be one created by a
server administrator.
Security administrator Disallowed N/A
Read-only users Disallowed N/A
Technicians Disallowed N/A
Completion Codes:
v MAX_VOLUMES_REACHED
Maximum number of volumes already defined
v CONS_GROUP_BAD_NAME
Consistency Group name does not exist.
v SNAPSHOT_GROUP_BAD_NAME
Snapshot Group name does not exist.
v SNAPSHOT_GROUP_BAD_PREFIX
Snapshot Group name has a reserved prefix.
v SNAPSHOT_GROUP_NAME_EXISTS
Snapshot Group name already exists.
v CONS_GROUP_EMPTY
Operation is not allowed on an empty Consistency Group.
v CONS_GROUP_MISMATCH
Snapshot Group does not match Consistency Group volumes.
v OVERWRITE_SNAPSHOT_GROUP_DOES_NOT_BELONG_TO_GIVEN_GROUP
Chapter 7. Snapshot Set Management 103

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM XIV and is the answer not in the manual?

IBM XIV Specifications

General IconGeneral
Power SupplyRedundant power supplies
Drive TypeSATA
RedundancyFully redundant components
ConnectivityFibre Channel, iSCSI
Form FactorRack-mounted
CacheDistributed cache across modules
Data ProtectionSnapshots, remote mirroring
PerformanceHigh throughput and low latency
ScalabilityModular, scale-out architecture
CoolingRedundant cooling
ArchitectureGrid-based, distributed architecture

Related product manuals