EasyManuals Logo

IBM XIV User Manual

IBM XIV
652 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #417 background imageLoading...
Page #417 background image
Troubleshooting: Please restart the key server gateway node and retry.
v NO_MASTER_KEYSERVER_DEFINED
There is no master key server defined on the system.
Troubleshooting: Please define a master key server by invoking encrypt_key
server_update and retry.
v KEYSERVER_COMMUNICATION_GENERIC_ERROR
Cannot connect to an active key server.
Troubleshooting: Invoke encrypt_key server_list and event_list for more details.
Testing a Component
Tests a hardware component.
component_test component=ComponentId
Parameters:
Name Description Mandatory
component Component ID. Y
This command instructs the XIV system to test the component. The command is
used after a failed component is replaced. Components must be in a Failed status.
Upon a successful test, the component changes to Ready status. Upon a failed test,
the component remains in a Failed state.
Access Control:
User Category Permission
Storage administrator Disallowed
Storage integration administrator Disallowed
Application administrator Disallowed
Security administrator Disallowed
Read-only users Disallowed
Technicians Allowed
Warnings:
v ARE_YOU_SURE_YOU_WANT_TO_HARD_RESET_MODULE
Are you sure you want to hard reset the module?
Completion Codes:
v COMPONENT_DOES_NOT_EXIST
Component does not exist
v TEST_NOT_SUPPORTED_FOR_THIS_COMPONENT_TYPE
This component type cannot be tested
v DISK_IS_NOT_FUNCTIONING
Disk is not functioning.
Troubleshooting: Replace disk
v TEST_NOT_ALLOWED_IN_CURRENT_STATUS
Component cannot be tested in its current status
Chapter 20. Hardware Maintenance 411

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM XIV and is the answer not in the manual?

IBM XIV Specifications

General IconGeneral
Power SupplyRedundant power supplies
Drive TypeSATA
RedundancyFully redundant components
ConnectivityFibre Channel, iSCSI
Form FactorRack-mounted
CacheDistributed cache across modules
Data ProtectionSnapshots, remote mirroring
PerformanceHigh throughput and low latency
ScalabilityModular, scale-out architecture
CoolingRedundant cooling
ArchitectureGrid-based, distributed architecture