Timestamp Severity Code
2009-05-12 15:10:16 Informational START_WORK
2009-05-12 15:16:11 Informational POOL_CREATE
2009-05-12 15:16:22 Critical WOULD_BE_EMERGENCY_SHUTDOWN
2009-05-12 15:16:23 Informational VOLUME_CREATE
Additional output fields
(lines are broken to fit the page width of this Guide):
User Description
System has entered ON state.
xiv_development Storage Pool of size 171GB was created with name
’p1_m’.
An emergency shutdown has been detected, but UPS control
is disabled.
xiv_development Volume was created with name ’master’ and size 17GB in
Storage Pool with name ’p1_m’.
Access Control:
User Category Permission Condition
Storage administrator Conditionally Allowed Only the technician can run this
command with the internal
parameter
Storage integration administrator Disallowed N/A
Application administrator Conditionally Allowed Only the technician can run this
command with the internal
parameter
Security administrator Conditionally Allowed Only the technician can run this
command with the internal
parameter
Read-only users Conditionally Allowed Only the technician can run this
command with the internal
parameter
Technicians Allowed N/A
Completion Codes:
v UNRECOGNIZED_EVENT_CODE
'String' is not a recognized event code
Troubleshooting: Consult the manual for the list of event codes
v CANNOT_READ_EVENTS
Cannot read events.
Troubleshooting: Contact support
Listing Uncleared Alerting Events
Lists uncleared alerting events.
event_list_uncleared
This command lists uncleared alerting events.
Example:
event_list_uncleared
280 IBM XIV Storage System User Manual

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM XIV and is the answer not in the manual?

IBM XIV Specifications

General IconGeneral
Power SupplyRedundant power supplies
Drive TypeSATA
RedundancyFully redundant components
ConnectivityFibre Channel, iSCSI
Form FactorRack-mounted
CacheDistributed cache across modules
Data ProtectionSnapshots, remote mirroring
PerformanceHigh throughput and low latency
ScalabilityModular, scale-out architecture
CoolingRedundant cooling
ArchitectureGrid-based, distributed architecture

Related product manuals