Start UPS calibration
Example:
xcli -u -c XIV1 ups_start_calibration ups
Access Control:
User Category Permission
Storage administrator Disallowed
Storage integration administrator Disallowed
Application administrator Disallowed
Security administrator Disallowed
Read-only users Disallowed
Technicians Allowed
Completion Codes:
v UPS_IS_UNMONITORED
The specified UPS is not monitored and commands cannot be run on it
Troubleshooting: Contact support
v COMPONENT_DOES_NOT_EXIST
Component does not exist
v UPS_ALREADY_IN_CALIBRATION
UPS calibration is already pending or in progress
Troubleshooting: Contact support
v FIRMWARE_UPGRADE_IN_PROGRESS
Firmware upgrade in progress
Troubleshooting: Contact support
Start UPS Self Test
Start UPS self test
ups_start_self_test ups=ComponentId
Parameters:
Name Description Mandatory
ups The UPS to test Y
Start UPS self test
Example:
xcli -u -c XIV1 ups_start_self_test ups
Output: