EasyManuals Logo

IBM XIV User Manual

IBM XIV
652 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #112 background imageLoading...
Page #112 background image
Command completed successfully.
Access Control:
User Category Permission Condition
Storage administrator Allowed N/A
Storage integration administrator Allowed N/A
Application administrator Conditionally Allowed At least one of the volumes in
the master Consistency Group is
mapped to a host or cluster
associated with the user and
Snapshot Group was created by
a server administrator
Security administrator Disallowed N/A
Read-only users Disallowed N/A
Technicians Disallowed N/A
Completion Codes:
v SNAPSHOT_GROUP_BAD_NAME
Snapshot Group name does not exist.
v SNAPSHOT_IS_MAPPED
Snapshot that is mapped to a host cannot be deleted
v SNAPSHOT_HAS_ACTIVE_SYNC_JOB
Snapshot is currently a target of an active sync job
Troubleshooting: Please wait for sync job to complete
Disbanding a Snapshot Group
Disbands a snapshot group into independent snapshots.
snap_group_disband snap_group=SnapshotGroupName
Parameters:
Name Type Description Mandatory
snap_group Object name Snapshot group to be
disbanded.
Y
This command disbands the snapshot group into independent snapshots. After
executing this command the snapshots can be individually deleted, restored,
unlocked, duplicated and so on. The snapshot group does not exist anymore after
this command. The snapshots retain the same names
(snap_group_name.volumename).
The command is inapplicable for a snapshot group of a mirrored Consistency
Group.
Example:
snap_group_disband snap_group=DBbackup_copy
106 IBM XIV Storage System User Manual

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM XIV and is the answer not in the manual?

IBM XIV Specifications

General IconGeneral
Power SupplyRedundant power supplies
Drive TypeSATA
RedundancyFully redundant components
ConnectivityFibre Channel, iSCSI
Form FactorRack-mounted
CacheDistributed cache across modules
Data ProtectionSnapshots, remote mirroring
PerformanceHigh throughput and low latency
ScalabilityModular, scale-out architecture
CoolingRedundant cooling
ArchitectureGrid-based, distributed architecture

Related product manuals