v UPGRADE_RELATED_SCRIPT_ALREADY_RUNNING
Pre-upgrade or post-upgrade script cannot be invoked since an upgrade related
script is currently running
v SYSTEM_UPGRADE_INCOMPATIBLE_UPGRADE_TYPE_SPECIFIED
The specified upgrade type specified is incompatible with the kind of change
imposed by the new version's files
Troubleshooting: Specify the correct upgrade type
Validating the Prerequisites of an Upgrade to a New Software Version
Validates the ability to upgrade to a specified system version
upgrade_validate_prerequisites [ upgrade_type=<hot|utilities_only> ]
Parameters:
Name Type Description Mandatory Default
upgrade_
type
Enumeration The type can can
be "hot" (for hot
upgrade) or
"utilities_only" (for
warm upgrade).
N hot
This command runs the prerequisites validation script of the upgrade, and returns
its result.
Access Control:
User Category Permission
Storage administrator Disallowed
Storage integration administrator Disallowed
Application administrator Disallowed
Security administrator Disallowed
Read-only users Disallowed
Technicians Allowed
Completion Codes:
v PRE_UPGRADE_VALIDATIONS_ALREADY_RUNNING
Pre-upgrade validations cannot be invoked since the system is already in the
process of performing those validations
v UPGRADE_RELATED_SCRIPT_ALREADY_RUNNING
Pre-upgrade or post-upgrade script cannot be invoked since an upgrade related
script is currently running
v SYSTEM_UPGRADE_NOT_FINISHED_DOWNLOADING
System cannot switch to new version until the new version is downloaded to all
modules of the system.
Troubleshooting: Make sure that all nodes finished downloading the new
software version
v PRE_UPGRADE_VALIDATION_FAILED
One or more of the conditions for starting an upgrade sequence failed
Chapter 9. System Management 165