Access Control:
User Category Permission
Storage administrator Allowed
Storage integration administrator Disallowed
Application administrator Allowed
Security administrator Disallowed
Read-only users Disallowed
Technicians Allowed
Completion Codes:
v IB_PORT_NOT_VALID
Illegal number for IB port was given.
Collecting IB Switch Logs
Collect IB switch logs.
ib_get_switch_logs ib_switch=ComponentId target_module=ComponentId
Parameters:
Name Description Mandatory
ib_switch Component specification of
infiniband switch.
Y
target_
module
The target module to put the log
in.
Y
Removes existing infiniband port from configuration. Port must be defined in the
configuration.
Example:
xcli -u -c XIV1 ib_get_switch_logs ib_switch=1:IB_Switch:1
Access Control:
User Category Permission
Storage administrator Allowed
Storage integration administrator Disallowed
Application administrator Allowed
Security administrator Disallowed
Read-only users Disallowed
Technicians Allowed
Completion Codes:
v IB_SWITCH_NOT_PRESENT
Specified switch is not defined in the system or the switch value is not valid.
Chapter 17. Infiniband 351

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM XIV and is the answer not in the manual?

IBM XIV Specifications

General IconGeneral
Power SupplyRedundant power supplies
Drive TypeSATA
RedundancyFully redundant components
ConnectivityFibre Channel, iSCSI
Form FactorRack-mounted
CacheDistributed cache across modules
Data ProtectionSnapshots, remote mirroring
PerformanceHigh throughput and low latency
ScalabilityModular, scale-out architecture
CoolingRedundant cooling
ArchitectureGrid-based, distributed architecture