Local volume does not have remote mirroring definitions
v CONS_GROUP_BAD_NAME
Consistency Group name does not exist.
v CONS_GROUP_NO_MIRROR
Local Consistency Group does not have remote mirroring definitions
v LOCAL_PEER_IS_NOT_MASTER
Local peer is not the master
v MIRROR_DESIGNATION_NOT_SUPPORTED_BY_TARGET
Mirror role designation is not supported by the Mirror's Target.
v MIRROR_IS_NON_OPERATIONAL
Mirror is non-operational
v VOLUME_BELONGS_TO_MIRRORED_CONS_GROUP
Volume mirror is part of Consistency Group mirror.
Changing a Mirroring Schedule for Remote Slave Peers
Changes the replication schedule of a remote Slave peer.
mirror_change_remote_schedule < vol=VolName |
cg=cgName > remote_schedule=Schedule
Parameters:
Name Type Description Mandatory
vol Object name Local master volume
name
N
cg Object name Local master CG name N
remote_
schedule
Object name A reference to a remote
schedule that should be
set for the remote slave
peer (which
corresponds with the
Master specified in the
command)
Y
This command changes the replication schedule of an asynchronous coupling in
order to make it effective after the role of a specified remote Slave peer is changed
to Master.
Prerequisites:
v The coupling must be ASYNC_INTERVAL.
Following the command execution:
v The system displays a warning
v If the command is approved, it is executed
v An event is generated
v New sync jobs are generated according to the updated schedule
v Existing sync jobs are not affected (i.e. they run according to the previous
schedule)
Requirements for a successful command completion:
208 IBM XIV Storage System User Manual

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM XIV and is the answer not in the manual?

IBM XIV Specifications

General IconGeneral
Power SupplyRedundant power supplies
Drive TypeSATA
RedundancyFully redundant components
ConnectivityFibre Channel, iSCSI
Form FactorRack-mounted
CacheDistributed cache across modules
Data ProtectionSnapshots, remote mirroring
PerformanceHigh throughput and low latency
ScalabilityModular, scale-out architecture
CoolingRedundant cooling
ArchitectureGrid-based, distributed architecture

Related product manuals