Listing Events
Lists system events.
event_list [ max_events=MaxEventsToList ]
[ after=TimeStamp ]
[ before=TimeStamp ]
[ min_severity=<INFORMATIONAL|WARNING|MINOR|MAJOR|CRITICAL> ]
[ alerting=<yes|no|all> ]
[ cleared=<yes|no|all> ]
[ code=EventCode ]
[ object_type=<cons_group|destgroup|dest|dm|host|map|
mirror|pool|rule|smsgw|smtpgw|target|volume|
cluster|ip_interface|ldap_conf|meta_data_object|
sync_schedule|user|user_group|ldap_server|modules_status|
elicense|ipsec_connection|ipsec_tunnel|cross_cons_group,...> ]
[ internal=<yes|no|all> ]
[ beg=BeginIndex ] [ end=EndIndex ]
[ count_all=<yes|no> ]
Parameters:
Name Type Description Mandatory Default
max_events Positive integer Maximum number
of events to list.
N 300.
after N/A Earliest time/date. N no filter.
before N/A Latest time/date. N no filter.
min_
severity
Enumeration Minimum severity. N no filter.
alerting Boolean Filter alerting
events.
N no filter.
cleared Boolean Filter cleared
events.
N no filter.
code N/A Filter by a specific
event code.
N no filter.
object_
type
Enumeration Filter events by the
type of the related
system object.
N no filter.
internal Boolean Filter XIV internal
events.
N no filter.
beg Integer Index of the first
event to list. If
negative, then
counts from the
end.
N1.
end Integer Index of the last
event to list (not
inclusive). If
negative, then
counts from the
end.
N last event + 1.
count_all Boolean If yes, it scans all
the events between
beg and end for
computing the
number of events
meeting the
criteria.
N no.
278 IBM XIV Storage System User Manual

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM XIV and is the answer not in the manual?

IBM XIV Specifications

General IconGeneral
Power SupplyRedundant power supplies
Drive TypeSATA
RedundancyFully redundant components
ConnectivityFibre Channel, iSCSI
Form FactorRack-mounted
CacheDistributed cache across modules
Data ProtectionSnapshots, remote mirroring
PerformanceHigh throughput and low latency
ScalabilityModular, scale-out architecture
CoolingRedundant cooling
ArchitectureGrid-based, distributed architecture

Related product manuals