Listing Modules Internal Temperatures
Lists the modules' internal temperatures in the XIV system.
module_temperature_list [ module=ModuleNumber ]
Parameters:
Name Description Mandatory Default
module Limits the listing to a
specific module.
N All temperatures in all
modules.
This command lists the modules' internal temperatures in the XIV system.
Example:
module_temperature_list -f all
Output:
root@nextra-6002207-module-1:~# xcli.py module_temperature_list
Module Normalized Ambient Raw Ambient Midplane EM Card Fan Controller
------------- -------------------- ------------- ---------- --------- ----------------
1:Module:1 18 17 20 23 24
1:Module:10 17 22 20 25 20
1:Module:13 18 24 21 26 22
1:Module:4 17 18 20 23 22
1:Module:7 18 20 20 25 26
CPU 1 DIMM 2 DIMM 4 DIMM 6 PCIe InfiniBand HCA Fibre Channel Port fc-0
------- -------- -------- -------- ------ ---------------- -------------------------
36 29 29 28 31 62
39 31 31 29 35 65
40 31 31 30 35 69
33 30 29 28 34 62 52
36 30 29 28 36 71 50
Fibre Channel Port fc-2
-------------------------
51