Page #437 background image
Access Control:
User Category Permission
Storage administrator Allowed
Storage integration administrator Disallowed
Application administrator Allowed
Security administrator Disallowed
Read-only users Allowed
Technicians Allowed
Listing Modules Internal Temperatures
Lists the modules' internal temperatures in the XIV system.
module_temperature_list [ module=ModuleNumber ]
Parameters:
Name Description Mandatory Default
module Limits the listing to a
specific module.
N All temperatures in all
modules.
This command lists the modules' internal temperatures in the XIV system.
Example:
module_temperature_list -f all
Output:
root@nextra-6002207-module-1:~# xcli.py module_temperature_list
Module Normalized Ambient Raw Ambient Midplane EM Card Fan Controller
------------- -------------------- ------------- ---------- --------- ----------------
1:Module:1 18 17 20 23 24
1:Module:10 17 22 20 25 20
1:Module:13 18 24 21 26 22
1:Module:4 17 18 20 23 22
1:Module:7 18 20 20 25 26
CPU 1 DIMM 2 DIMM 4 DIMM 6 PCIe InfiniBand HCA Fibre Channel Port fc-0
------- -------- -------- -------- ------ ---------------- -------------------------
36 29 29 28 31 62
39 31 31 29 35 65
40 31 31 30 35 69
33 30 29 28 34 62 52
36 30 29 28 36 71 50
Fibre Channel Port fc-2
-------------------------
51
51
Id Name Default Position
component_id Module 1
Chapter 20. Hardware Maintenance
431

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM XIV and is the answer not in the manual?

IBM XIV Specifications

General IconGeneral
Power SupplyRedundant power supplies
Drive TypeSATA
RedundancyFully redundant components
ConnectivityFibre Channel, iSCSI
Form FactorRack-mounted
CacheDistributed cache across modules
Data ProtectionSnapshots, remote mirroring
PerformanceHigh throughput and low latency
ScalabilityModular, scale-out architecture
CoolingRedundant cooling
ArchitectureGrid-based, distributed architecture

Related product manuals