The following commands are no longer in use:
v mirror_change_config (Command is no longer in use in this version. Parameter
create_last_consistent_snapshot is associated directly with pools)
v sync_rates_set (Command is no longer in use in this version. Supplanted by
command target_config_sync_rates.)
Canceling a Snapshot Mirror (Ad Hoc Sync Job)
Cancels all Snapshot Mirrors ('ad-hoc' sync jobs) of a specified master volume or a
master Consistency Group, that have not run yet.
mirror_cancel_snapshot <vol=VolName | cg=cgName>
Parameters:
Name Type Description Mandatory
vol Object name Name of the (local)
master volume whose
non-started snapshot
mirrors should be
cancelled
N
cg Object name Name of the (local)
master Consistency
Group whose
non-started snapshot
mirrors should be
cancelled
N
This command cancels all snapshot mirrors (ad-hoc sync jobs) for a specific master
volume, or a master Consistency Group. Only sync jobs that haven't started are
cancelled. The command does not delete the snapshots themselves.
Upon running the command:
v A warning message is presented to the user for confirmation.
v An event is generated.
v Non-started snapshot mirrors are cancelled.
The command fails under the following conditions:
v The command is issued on a slave volume or Consistency Group.
Access Control:
User Category Permission Condition
Storage administrator Allowed N/A
Storage integration administrator Allowed N/A
Application administrator Conditionally Allowed The volume is mapped to a host
or a cluster associated with the
user. If a snapshot overwrite is
used, the target snapshot must
be one created by a server
administrator.
Security administrator Disallowed N/A
Read-only users Disallowed N/A
Technicians Disallowed N/A
198 IBM XIV Storage System User Manual

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM XIV and is the answer not in the manual?

IBM XIV Specifications

General IconGeneral
Power SupplyRedundant power supplies
Drive TypeSATA
RedundancyFully redundant components
ConnectivityFibre Channel, iSCSI
Form FactorRack-mounted
CacheDistributed cache across modules
Data ProtectionSnapshots, remote mirroring
PerformanceHigh throughput and low latency
ScalabilityModular, scale-out architecture
CoolingRedundant cooling
ArchitectureGrid-based, distributed architecture