Name Type Description Mandatory
local_
ipinterfac
e
Object name Local IP interface to be
connected to the remote
port (iSCSI only).
N
fcaddress N/A FC address of the port
on the remote target
(FC targets only).
N
local_port N/A FC port (FC only). N
This command defines connectivity between a port on the local storage system and
a port on a remote target.
Connectivity between a local and a target storage system is defined between a
specific port on a local storage system and a port on the target storage system.
Each connectivity definition can be either active or inactive. The system does not
use an inactive connectivity definition. Target Connectivity is active by default. An
option is provided to de-activate (target_connectivity_deactivate) and then
re-activate (target_connectivity_activate) it, if required. Target Connectivity can be
deleted (Deleting Connectivity to a Remote Target) and a list of Target Connectivity
definitions (Listing Target Connectivity Definitions) can be displayed.
Access Control:
User Category Permission
Storage administrator Allowed
Storage integration administrator Allowed
Application administrator Disallowed
Security administrator Disallowed
Read-only users Disallowed
Technicians Disallowed
Completion Codes:
v TARGET_BAD_NAME
Target name does not exist
v CONN_EXISTS
Remote port is already connected through this local port
v MAX_CONNECTIONS_REACHED
Maximum number of connections already defined
v MAX_ISCSI_CONNECTIONS_PER_MODULE_REACHED
Maximal number of iSCSI connectivities already defined for that module.
v COMPONENT_IS_NOT_AN_FC_PORT
Component must specify an FC port
v COMPONENT_IS_NOT_FC_TARGET_PORT
Component must specify FC target port
v BAD_LOCAL_IP_PORT
An ID of a local IP port must be specified
v COMMAND_NOT_ALLOWED_ON_MANAGEMENT_INTERFACE
Chapter 10. Remote Target Connectivity 181