EasyManuals Logo

IBM XIV User Manual

IBM XIV
652 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #404 background imageLoading...
Page #404 background image
Parameters:
Name Type Description Mandatory Default
host Object name Limits viewing to
the ports of a
specific host.
N All hosts.
fc_host_
port
N/A Limits viewing to
this specific port.
N All ports
module N/A Limits output to
only enable
connectivity to this
module.
N All modules
fcport N/A Limits output to
this specific XIV
port.
N All ports
This command shows the connectivity status between a XIV port and a defined
host. The output can be limited to a specific port, module or XIV port. Hosts can
attach to the FC and iSCSI either directly (point-to-point), via an FC fabric or via a
Gigabit Ethernet switch. Connectivity refers to both physical connectivity and SCSI
log in. Each output line contains the following information:
v Host (name)
v Host port (WWPN)
v XIV module (rack_id:module_id)
v XIV port number (within the module)
v Boolean-connected Y/N (login)
Output:
Host Host Port Module Local FC port Local iSCSI port Type
----------------- ----------------- ------------ --------------- ------------------ ------
tlib_host_host076 100000062B151A98 1:Module:5 1:FC_Port:5:1 FC
Id Name Default Position
host Host 1
host_port Host Port 2
module Module 3
local_fc_port Local FC port 4
local_iscsi_
port
Local iSCSI port 5
type Type 6
Access Control:
User Category Permission
Storage administrator Allowed
Storage integration administrator Disallowed
Application administrator Allowed
Security administrator Disallowed
Read-only users Allowed
398 IBM XIV Storage System User Manual

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM XIV and is the answer not in the manual?

IBM XIV Specifications

General IconGeneral
Power SupplyRedundant power supplies
Drive TypeSATA
RedundancyFully redundant components
ConnectivityFibre Channel, iSCSI
Form FactorRack-mounted
CacheDistributed cache across modules
Data ProtectionSnapshots, remote mirroring
PerformanceHigh throughput and low latency
ScalabilityModular, scale-out architecture
CoolingRedundant cooling
ArchitectureGrid-based, distributed architecture