Once the phase-out process is completed, the component's state is either Fail or
Ready, depending on the argument markasfailed. If true, the phased-out component
is marked as a failed component (in order to replace the component). If false, the
phased-out component is in the Ready state.
Access Control:
User Category Permission
Storage administrator Disallowed
Storage integration administrator Disallowed
Application administrator Disallowed
Security administrator Disallowed
Read-only users Disallowed
Technicians Allowed
Completion Codes:
v PHASEOUT_NOT_SUPPORTED_FOR_THIS_COMPONENT_TYPE
This component type cannot be phased-out
v PHASEOUT_WILL_MAKE_SYSTEM_NON_REDUNDANT
Cannot phase out the component because it will cause data to be unprotected
v PHASEOUT_NOT_ALLOWED_IN_CURRENT_STATUS
Component cannot be phased-out in its current status
v COMPONENT_DOES_NOT_EXIST
Component does not exist
v COMPONENT_TYPE_CANNOT_BE_PHASED_OUT_AS_FAILED
Components of this type cannot be phased-out and marked as failed
v MODULE_CANNOT_BE_PHASED_OUT_DUE_TO_MANAGEMENT_
REQUIREMENT
Module cannot be phased out due to management requirement
Troubleshooting: Contact support
v CAN_NOT_PHASE_OUT_DISK_WITH_MARKASFAILED_NO
Disks cannot be phased-out with markasfailed=no
v COMPONENT_TYPE_MUST_BE_PHASED_OUT_AS_FAILED
Components of this type must be phased-out as failed
v USE_SERVICE_PHASEOUT_COMMAND
Command component_phaseout does not support services. Please use
service_phaseout.
v CONTAINING_COMPONENT_IN_WRONG_STATUS
Operation not allowed in current status of containing component.
v SUBCOMPONENT_IN_WRONG_STATUS
Operation not allowed in current status of a subcomponent.
v CONTROLLING_SERVICES_NOT_ALLOWED_FOR_USER_CATEGORY
Controlling services not allowed for user category
v NOT_ALL_PSUS_OK
There is one or more PSUs disconnected or failed, this may cause the requested
action to cause module failures
408 IBM XIV Storage System User Manual

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM XIV and is the answer not in the manual?

IBM XIV Specifications

General IconGeneral
Power SupplyRedundant power supplies
Drive TypeSATA
RedundancyFully redundant components
ConnectivityFibre Channel, iSCSI
Form FactorRack-mounted
CacheDistributed cache across modules
Data ProtectionSnapshots, remote mirroring
PerformanceHigh throughput and low latency
ScalabilityModular, scale-out architecture
CoolingRedundant cooling
ArchitectureGrid-based, distributed architecture