REMOTE_OPERATION_FAILED_TIMED_OUT
Severity warning
Description Operation on remote machine timed out. Invoking
'Function Name' on target 'Target Name' timed out.
Troubleshooting Retry operation. If problem persists contact
support.
MIRROR_RESYNC_FAILED
Severity major
Description Synchronization of meta data with mirror failed.
Configuration of remote mirror of volume 'local
volume name' on target 'target name' does not match
local configuration.
Troubleshooting Make sure configuration on both machines is
compatible and activate the mirror. If problem
persists contact support.
MIRROR_RESYNC_FAILED_DUE_TO_THIN_PROVISIONING
Severity major
Description Synchronization of bitmaps with mirror failed.
Not enough hard capacity left in Pool of volume
'mirror.local_volume_name'.
Troubleshooting Delete unnecessary volumes in pool or enlarge the
pool's hard size.
MIRROR_SYNC_STARTED
Severity informational
Description Synchronization of remote mirror of volume 'local
volume name' on Target 'target name' has started.
MIRROR_SYNC_ENDED
Severity informational
Description Synchronization of remote mirror of peer 'local
peer name' on target 'target name' has ended.
MIRROR_CANNOT_CREATE_SYNC_JOB_TOO_MANY_VOLUMES
Severity major
Description Synchronization of remote mirror of peer 'local
peer name' on target 'target name' can not be synced
, insufficent volume available for this operation.
MIRROR_CANNOT_CREATE_LRS_TOO_MANY_VOLUMES
Severity major
Chapter 24. Events
519

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM XIV and is the answer not in the manual?

IBM XIV Specifications

General IconGeneral
Power SupplyRedundant power supplies
Drive TypeSATA
RedundancyFully redundant components
ConnectivityFibre Channel, iSCSI
Form FactorRack-mounted
CacheDistributed cache across modules
Data ProtectionSnapshots, remote mirroring
PerformanceHigh throughput and low latency
ScalabilityModular, scale-out architecture
CoolingRedundant cooling
ArchitectureGrid-based, distributed architecture