Description Both PSUs on Module report critical failures, this is
probably because of a faulty PDB.
Troubleshooting Please contact support.
SES_AMBIENT_TEMPERATURE_SEVERITY_CHANGED
Severity variable
Description Module module sensor desc reports (readingC) state
desc.
Troubleshooting Adjust ambient temperature at this module intake.
SES_TEMPERATURE_SEVERITY_CHANGED
Severity variable
Description Module module sensor desc reports (readingC) state
desc.
Troubleshooting Please contact support.
SES_TEMPERATURE_OK
Severity informational
Description Module module sensor desc reports (readingC) state
desc.
Troubleshooting N/A
INVALID_USM_VERSION_FOUND
Severity minor
Description The USM version on Component is invalid
Troubleshooting Please contact support.
USM_VERSION_UNEXPECTED
Severity warning
Description USM on Component - unexpected code-level, found
'Label' which is old and should be upgraded
Troubleshooting Please contact support.
SES_VERSION_UNEXPECTED
Severity warning
Description SES on Component - unexpected enclosure
management code-level, found
Major.Minor.Level.Level2 which is old and should
be upgraded
Troubleshooting Please contact support.
PDB_FIRMWARE_VERSION_UNEXPECTED
Severity warning
Chapter 24. Events
593