Intel® Server System S7000FC4UR TPS Sensors
Revision 1.0
291
Rearm Sensors
- The rearm is a request for the event status for a sensor to be rechecked and
updated upon a transition between good and bad states. Rearming the sensors can
be done manually or automatically. This column indicates the type supported by the
sensor. The following abbreviations are used in the comment column to describe a
sensor:
A: Auto-rearm
M: Manual rearm
Default Hysteresis
- Hysteresis setting applies to all thresholds of the sensor. This column provides the
count of hysterisis for the sensor, which can be 1 or 2 (positive or negative
Hysteresis).
Criticality
- Criticality is a classification of the severity and nature of the condition. It also controls
the behavior of the Front Panel Status LED (see Table 6, System Status LED
Indicator States.
Standby
- Some sensors operate on standby power. These sensors may be accessed and / or
generate events when the main (system) power is off, but AC power is present.

Table of Contents