Intel® Server System S7000FC4UR TPS Sensors
Revision 1.0
293
Sensor Name
3
Sensor # Sensor Type Event /
Reading Type
Event Offset
Triggers
Contrib. To
System Status
Assert /
De-assert
Readable
Value /
Offsets
Event
Data
Rearm Stand-
by
Platform Security
Violation
04h Platform
Security
Violation
Attempt
06h
Sensor
Specific
6Fh
Secure mode
violation attempt
OK As and
De
– Trig
Offset
A X
Chassis intrusion OK X Physical Security 05h Physical
Security
05h
Sensor
Specific
6Fh
LAN least lost Degraded
As and
De
– Trig
Offset
A
FP Diag Interrupt
(NMI)
07h Critical
Interrupt
13h
Sensor
Specific
6Fh
Front panel NMI /
diagnostic
interrupt
Bus uncorrectable
error
OK As Trig
Offset
A –
System Event Log 09h Event
Logging
Disabled
10h
Sensor
Specific
6Fh
Log area reset /
cleared
OK As Trig
Offset
A X
Session Audit 0Ah Session Audit
2Ah
Sensor
Specific
6Fh
00h – Session
activation
01h – Session
deactivation
OK As As
defined
by IPMI
A X
System Event
('System Event')
0Bh System Event
12h
Sensor
Specific
6Fh
00 – System
reconfigured
04 – PEF action
OK As Trig
Offset
A X
BB Temp 30h Temperature
01h
Threshold
01h
[u,l] [c,nc] nc =
Degraded
c = Non-fatal
As and
De
Analog R, T A X
FP Temp 32h Temperature
01h
Threshold
01h
[u,l] [c,nc] nc =
Degraded
c = Non-fatal
As and
De
Analog R, T A X
Reserved for future
use
33h _ _ _ _ _ _ _ _ _

Table of Contents

Other manuals for Intel S7000FC4UR

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intel S7000FC4UR and is the answer not in the manual?

Intel S7000FC4UR Specifications

General IconGeneral
BrandIntel
ModelS7000FC4UR
CategoryServer
LanguageEnglish

Related product manuals