EasyManua.ls Logo

Intel S7000FC4UR - Functional Architecture

Intel S7000FC4UR
345 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Intel® Server System S7000FC4UR TPS Main Board Server Management
Revision 1.0
33
BMC internal timeclock sync with SIO RTC: At BMC startup, the BMC reads the SIO
RTC and updates its internal timeclock. The BMC updates the SIO RTC when it receives
the Set SEL Time IPMI command from the BIOS.
Chassis intrusion fan interactions: Fans go to high speed when the chassis intrusion
signal is asserted.
PCI-Express* link status monitoring support: The BMC maintains sensors for PCI-
Express status and provides interface commands for the BIOS to push state information
to the BMC.
Intel
®
Remote Management Module 2 support: The BMC supports an add-in that uses its
own dedicated NIC, the GCM3 NIC, to provide advanced server management features
via Out of band.
Platform environment control interface (PECI) thermal management support
3.2 Functional Architecture
This section provides block diagrams of the server management architecture.

Table of Contents

Other manuals for Intel S7000FC4UR

Related product manuals