BIOS Role in Server Management ESB2 BMC Core TPS
Revision 1.0
Intel order number E18291-001
220
Offset Name Length Value Description
Bit 3
1b = interrupt information specified
0b = interrupt information not
specified
Bit 2
Reserved: Return as 00000b.
Bit 1 Interrupt polarity
1b = active high
0b = active low
Bit 0 Interrupt Trigger Mode
1b = level
0b = edge
11h Interrupt
Number
Byte Varies Interrupt number for IPMI system interface.
00h = Unspecified / unsupported
18.5.3.18 Type 126 Structure – Inactive
The System Management BIOS Reference Specification, Version 2.5 indicates any static
structure describing a feature(s) not supported in the current system configuration may be
marked as Type 126 Inactive.
The BIOS marks any static structures describing any system attributes not supported by the
current system configuration as Inactive in accordance with the System Management BIOS
Reference Specification, Version 2.5.
18.5.3.19 Type 127 Structure — End-of-Table
The SMBIOS Type 127 structure identifies the end of the structure table that might be earlier
than the last byte within the buffer specified by the structure. To ensure backward compatibility
with management software written to previous versions of the SMBIOS specification, the
structure table is still reported as a fixed-length. The entire length of the table can still be
indexed. If the end-of-table indicator is used in the last physical structure in a table, the field’s
length is encoded as four.
18.6 Security
The BIOS uses passwords to prevent unauthorized tampering with the server setup. Both user
and administrator passwords are supported by the BIOS.
18.6.1 Password
The maximum length of the password is seven characters. The password cannot have
characters other than alphanumeric (a-z, A-Z, 0-9). It is case sensitive. Once set, a password
can be cleared by changing it to a null string.
An Administrator password must be entered in order to set the user password. If only one
password is set, this password is required to enter BIOS Setup.

Table of Contents

Other manuals for Intel S7000FC4UR

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intel S7000FC4UR and is the answer not in the manual?

Intel S7000FC4UR Specifications

General IconGeneral
BrandIntel
ModelS7000FC4UR
CategoryServer
LanguageEnglish

Related product manuals