Main Board Intel® Server System S7000FC4UR TPS
Intel order number E18291-001
24
If the jumper is covering pins 1-2 on a 100/110VAC circuit, the server is allowed to
consume up to 1180 watts. This setting may cause a circuit breaker to trip.
If the jumper is covering pins 2-3 on a 115/120/127VAC circuit, the server power
consumption threshold is set to 1030 watts. The lower power threshold may be
exceeded, limiting system performance.
2.2.21 Power Delivery Block Diagram
The main board takes in P12V (+12V) and P3V3_STBY (3.3V Standby) voltage rails from the
system power distribution board. These rails are used to generate the specialized power rails
required by components on the main board and are distributed through the main board to other
boards in the board set. Figure 4 shows the power delivery flow used on the main board.