CK721-A Installation and Operation CK721-A User Interface
24-10349-8 Rev. B 4-21
This document contains confidential and proprietary information of Johnson Controls, Inc.
© 2012 Johnson Controls, Inc.
Input Terminal To g g le A (Y) indicates an input or input/output module
has this terminal address.
Output Terminal Toggle A (Y)
indicates an input/output module has this
terminal address.
Reader Terminal Toggle A (Y)
indicates a two reader module has this
terminal address.
Reader Mode To g g le Choices are: A (Access)
E (Entry)
X (Exit)
Card Processing Toggle Choices are: L (Local Mode)
C (Central Mode)
S (Shared Mode)
Access Time User Def. Values range from 0 to 25 seconds, with 5
se
conds as default. This represents the time
the door strike remains energized after a valid
card request.
Shunt Time User Def. Values range from 0 to 255 seconds. This
r
epresents the amount of time the door open
alarm is suppressed after a valid card access
request. (Note: After an access grant, the
shunt time will be cancelled once the door
status changes to locked and closed, even if
the shunt time has not yet expired.)
Door Open
Warning
User Def. Values range from 0 to 255 seconds. This
r
epresents the time prior to the expiration of
the shunt time that the warning output is
activated.
Door Open Warning
O
utput Group
User Def. Enter the number of the output group (1-600)
that will be activated for the open door
warning. (0 means no group is assigned.)
When the output group is activated,
is will not
de-activate by itself. Additional settings, like
Timed Duration of each output point in the
group, is needed for automatic de-activation.
Anti-Passback Togg l e If enabled (Y),
the reader is designated as an
Anti-Passback reader. Use Anti-Passback
Time to set the number of minutes a card
remains invalid at Anti-Passback readers after
the card has been granted access at an
Anti-Passback reader.
Table 4-6: Terminal Screen, Page 1
Field Type Description