EasyManua.ls Logo

JUMO DICON touch - Program Controller

JUMO DICON touch
196 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
123
12 Configuration
12.12 Program controller
You can choose here between the program controller and the fixed-setpoint controller. With the
fixed-setpoint controller, all program functions are deactivated and the setpoint values are
switched, as described in Chapter 11.4 "Setpoint values", page 64.
Setup dialog for fixed-setpoint controller
With the fixed-setpoint controller, all additional program functions are grayed out and therefore
inactive.
Setup dialog for program controller
Parameters
Parameter Selection/settings Description
Function Fixed-setpoint controller All additional parameters are grayed
out for this setting.
Program controller
Program start From program start Program is started at the start
Actual value ... at current actual value ...
Time ... at a given time.
In the event of power failure Abort The program is aborted following a
power failure.

Table of Contents

Other manuals for JUMO DICON touch

Related product manuals