Malfunctions - Causes and Remedies
274
Pos: 58.9 /Übersc hriften/Übersc hriften 2/P-T/ SStörungen an der zentralen Ke ttenschmieru ng @ 35\mod_12 56199185431 _78.docx @ 327048 @ 2 @ 1
16.2 Malfunctions on the central chain lubrication system
Pos: 58.10 /BA/Stör ungen - Ursa chen und Be hebung/Rundball enpressen/Ta bellarische A uflistung Kettensch mierung @ 2 40\mod_1395 153485543_7 8.docx @ 18918 08 @ @ 1
Malfunction
Possible cause
Remedy
Low oil consumption
Low pressure
Pump works with difficulty, dirt in the
pump area
Clean
Pump is not pressed to a full stroke
Adjust according to the operating
instructions
Pump valve does not close correctly
Remove and clean or replace
Oil is too thick
Replace with recommended oil
System contaminated
Clean or replace all measuring
valves
Oil consumption too high
Main pipe torn
Repair or replace
Oil too thin
Drive with thicker oil
Reduce the pump stroke
Machine is dry
No pressure
Pump not running
Repair, adjust or replace
Main pipe torn
Repair or replace
System has no oil
Vent the system (see chapter
Central chain lubrication system)
System blocked
Dirt
Clean the system and clean or
replace all measuring valves.
Pipe jammed
Repair or replace
Pump is not pressed to a full
stroke.
Oil is too thick, nozzles clogged.
Replace with recommended oil
Clean nozzles