EasyManua.ls Logo

Krone Comprima F 155 XC - 7.14 Menu 4 “Tying start delay” (chamber film wrapping)

Krone Comprima F 155 XC
430 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Terminal menus 7
Menu 4 “Tying start delay” (chamber film wrapping) 7.14
RP701-10 , RP701-11 , RP701-20 , RP701-21 , RP701-30 , RP701-31 , RP701-40 , RP701-41 , RP701-51
Comfort 1.0_en 45
n
4
1,0
0,0
0.0
s
EQG003-047
ü For The menu level is active, refer to page36.
ü Twine tying is selected in menu 8 "Type of tying",refer to page48.
To open the menu, press
.
Æ The display shows menu “Tying start delay”.
Adjusting the tying start delay
Increase or decrease the value, refer to page37.
To save the value, press
.
INFORMATION
KRONE recommends 0.0s as the tying start delay for twine tying.
7.14 Menu 4 “Tying start delay” (chamber film wrapping)
The time period between completion of the round bale in the bale chamber and activation of the
tying cycle is set using the tying start delay. The tying start delay is set in seconds.
Comprima F
Setting range: 0.0–1.0s
Comprima V
Setting range: 0.0–2.5s

Table of Contents

Other manuals for Krone Comprima F 155 XC