KRONE Operation Unit Alpha
99
Pos: 42.41 /Übersc hriften/Überschrif ten 3/P-T/S Sensortest digi tal @ 55\m od_12947525591 56_78.docx @ 534106 @ 3 @ 1
8.1.7 Sensor Test Digital
Pos: 42.42 /WHB/ Elektrik/Rundballe npresse/Alph a (Medium)/S ensortest digit al @ 83\mod_ 13171085327 24_78.docx @ 726779 @ @ 1
In the sensor test the sensors fitted on the machine are tested for their digital condition.
AB CD EF GH
2
3
6
7
8
10
RPM00003
Fig.
1. When switching operation on, keep the key pressed.
The pilot lamp (6) flashes slowly.
The LEDs of the bar graph (11) indicate whether the sensors are alive (iron in front of the
sensor).
• LED ON: Iron in front of the sensor
• LED OFF: No iron in front of the sensor
• LED flashing: Cable break on the sensor
Refer to the following table for the assignment of the sensors.
Note
You can use the and keys to switch back and forth between “Sensor Test /
Analogue” and “Sensor Test / Digital”.
Pos: 42.43 /La yout Module /---------------Seitenumbruch---------------- @ 0\mod_11961 75311226_0.doc x @ 4165 @ @ 1