7.25.1.3 Adjusting sensor B09/B10 “Filling display left/right”
Comprima V
15-1
1
state:
2,4V
1,9V
3,2V
1,9V
B08
B09
L
B10
R
1
2
3
EQG003-042
The sensor(3) is located behind the side hood:
B09 on the left side of the machine
B10 on the right side of the machine
The green bar in menu 15-1 “Sensor test” shows the saved value. The black bar shows the
current value of the sensor. As soon as a new value is saved, the green bar is adjusted to the
black one.
ü The bale chamber is closed and empty.
ü The density of the bale core is set in positionIII – “Low density of the bale core”, see
operating instructions, chapter Operation, “Adjusting the density of the bale core”.
ü Menu 15-1 “Sensor test” is open.
ü SensorB09 or B10 has been selected.
If the bar (2) is not inside the rectangle (1) when the bale chamber is closed and empty, adjust
sensorB09 or B10 mechanically:
Loosen the screw connections of the sensor and move it in the oblong hole until the bar (2)
is inside the rectangle (1) of the bargraph in the display.
ð An audio signal sounds if the bar (2) is inside the rectangle (1).
Tighten the screw connections on the sensor .
Press
.
Æ The set position is saved.
INFORMATION
Saving is only possible if the bar (2) is inside the rectangle (1) of the bargraph.