Krone Comprima F 155 XC - 7.25.1.1 Adjusting sensor B08 “Top blade cassette”

Krone Comprima F 155 XC
430 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Terminal menus 7
Menu 15 "Settings" 7.25
RP701-10 , RP701-11 , RP701-20 , RP701-21 , RP701-30 , RP701-31 , RP701-40 , RP701-41 , RP701-51
Comfort 1.0_en 61
Possible status displays of the sensors
Icon Designation
0
Sensor ready to operate
1
Sensor attenuated (metal in front of the sensor)
2
Sensor unattenuated (no metal in front of the sensor)
7
Cable break or short circuit
8
Defect in sensor or job computer
20 Cable break
21
Short circuit
7.25.1.1 Adjusting sensor B08 “Top blade cassette”
RP000-053
15-1
1
state:
5,0V
1,5V
1,0V
1,0V
1,0V
B08
B09
L
B05
EQ003-113
SensorB08 “Blade cassette up”(3) is located on the left side of the machine in the bottom part.
The green bar in menu 15-1 “Sensor test” shows the saved value. The black bar shows the
current value of the sensor. As soon as a new value is saved, the green bar is adjusted to the
black one.