EasyManua.ls Logo

Krone Comprima F 155 XC - 7.25.1 Menu 15-1 Sensor test

Krone Comprima F 155 XC
430 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Terminal menus 7
Menu 15 "Settings" 7.25
RP701-10 , RP701-11 , RP701-20 , RP701-21 , RP701-30 , RP701-31 , RP701-40 , RP701-41 , RP701-51
Comfort 1.0_en 59
7.25.1 Menu 15-1 "Sensor test"
WARNING
Danger of injury in the danger zone of the machine
If the PTO shaft runs during the sensor test, machine parts may start to move unintentionally.
Thus there is a risk of serious injuries or death.
Turn off PTO shaft.
In the sensor test, the sensors installed on the machine are checked for faults. Furthermore the
sensors can be correctly set in the sensor test. There is no guarantee the machine is working
correctly until after the sensors have been adjusted.
15-1
B01
B02
1
state:
8,3V
7,3V
5,2V
2,4V
7,9V
EQG003-030
ü Menu 15 “Settings” is called, refer to page58.
To open the menu, press
.
Æ The display shows the "Sensor test" menu.
Icon Designation Explanation
Select previous sensor
Select next sensor
Exit menu
Setting values:
The minimum and maximum setting value with attenuated sensor (metal in front of the sensor)
are shown in the upper part of the bar display. The current setting value (actual value) is
displayed under the bar display.
The distance from the sensor to the metal must be adjusted so that in the attentuated state the
bar is in the upper marking. Then check whether the bar is in unattenuated state in the lower
marked area.
Possible sensors (depending on the machine configuration)
An overview of the sensors, actuators and control units is provided in the circuit diagram in the
appendix.