EasyManua.ls Logo

Krone Comprima F 155 XC - 8.1.2 Remedying sensor;actuator error; 8.1.3 Error list

Krone Comprima F 155 XC
430 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Terminal error messages 8
Faults of the electrics/electronics 8.1
RP701-10 , RP701-11 , RP701-20 , RP701-21 , RP701-30 , RP701-31 , RP701-40 , RP701-41 , RP701-51
Comfort 1.0_en 73
FMI Meaning
15 The upper limit value has been reached.
16 The upper limit value has been exceeded.
17 The lower limit value has been reached.
18 The lower limit value has not been reached.
19 There is a CAN communication failure.
20 The data deviates upwards.
21 The data deviates downwards.
31 The condition has been fulfilled.
8.1.2 Remedying sensor/actuator error
Components must be repaired or replaced by a qualified specialist workshop only.
Before contacting the dealer, collect the following information about the error message:
Note the error number and the respective FMI (refer to page71) that are shown on the
display.
Shut down and safeguard the machine, Shutting down and safeguarding the machine.
Check sensor/actuator externally for damage.
Æ If the sensor/actuator is damaged, replace the sensor/actuator.
Æ If the sensor/actuator is not damaged, continue with the next test step.
Check connector cable and plug connection for damage and tightness.
Æ If the connector cable/plug connection is damaged, replace the connector cable/plug
connection.
Æ If the sensor/actuator is not damaged, continue with the next test step.
Perform an actuator test in case of an actuator error to identify the actuator status, refer to
page67.
If a sensor is defective, run a sensor test to identify the sensor status, refer to page59.
The more information the dealer has, the easier it is to eliminate the cause of the error.
8.1.3 Error list
General aspects on error causes
The sequence of the possible causes listed was selected so that the easiest tests with regard to
accessibility/handling are listed first which makes troubleshooting easier.
Following the stated references, you will get to the individual test steps of the possible error
causes. When all test steps have been processed and the error has still not been remedied, the
next possible cause must be checked or the next error in the error list of the terminal must be
remedied. The test steps do not contain the components to be tested in detail such as contacts,
plug designations etc. but must be selected by means of the circuit diagram.