7: Networking
EMG™ Edge Management Gateway User Guide 135
Figure 7-13 Network > Security
To enable FIPS:
1. Check the Enable FIPS Mode check box on the Networks > Security page.
2. Click Apply. The EMG unit will need to be rebooted to initiate FIPS mode. Once the EMG
module is running in FIPS mode, the Security page will display all processes that are running
in FIPS mode.
To disable FIPS:
1. Uncheck the Enable FIPS Mode check box on the Networks > Security page.
2. Click Apply. The EMG unit will need to be rebooted for this change to take effect.
HMAC DRBG Random number generator V (160/224/256/384/512 bits) and Key
(160/224/256/384/512 bits)
CTR DRBG (AES) Random number generator V (128 bits) and Key (AES 128/192/256
bits)
Algorithm Usage Key Sizes