17: Command Reference
EMGâ„¢ Edge Management Gateway User Guide 437
Description
Set RPM administrative password.
show RPM
Syntax
show rpm [type <ups|pdu>]
[config <sdorder|notify>]
[device <RPM Name or Id> [data <raw|logs|envmon>]]
Note: The show rpm envmon command for RPM-configured ServerTech Serial/Network
Mode is not supported by NUT/Powerman.
Description
Display a list of all RPMs, RPMs of a specific type, UPS shutdown and notification configuration, or
details and outlets for a single RPM device.
Script Commands
set script import
Syntax
set script import <interface|batch|custom> via <ftp|scp|copypaste>
[file <Script File>] [name <Script Name>] [host <IP Address
or Name>]
[login <User Login>] [path <Path to Script File>]
[filetype <expect|tcl|python>]
Note: Interface scripts will be given default/do user rights; Batch and Custom scripts will
be given admin/ad user rights. The name of the script will be the same as the file name (if
it is a valid script name), otherwise a script name must be specified for import.
Description
Import a script.
set script update
Syntax
set script update <interface|batch|custom> name <Script Name>
[group <default|power|admin>] [permissions <Permission List>]
Note: See 'help user permissions' for information on groups and user rights.

Table of Contents

Other manuals for Lantronix EMG Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lantronix EMG Series and is the answer not in the manual?

Lantronix EMG Series Specifications

General IconGeneral
BrandLantronix
ModelEMG Series
CategoryGateway
LanguageEnglish

Related product manuals