13: Connections
EMG™ Edge Management Gateway User Guide 284
Figure 13-6 Devices > Connections
2. For a device port, enter the following:
Outgoing
Connection
Timeout
Select to turn on or turn off the connection timeout:
No for no timeout
Yes for a timeout. Specify the number of seconds in the seconds field.
Port The number of the device port you are connecting.
This device port must be connected to an external serial device and must not have
command line interface logins enabled, be connected to a modem, or be running a
loopback test.
Note: To see the current settings for this device port, click the Settings link.
Data Flow Select the arrow showing the direction (bidirectional or unidirectional) the data will flow in
relationship to the device port you are connecting.
to From the drop-down list, select a destination for the connection: a device port connected
to a serial device, a device port connected to a modem, or an outbound network
connection (Telnet out, SSH out, TCP Port, or UDP Port).
Note: To see the current settings for a selected device port, click the Settings link.
Hostname
The host name or IP Address of the destination. This entry is required if the to field is set
to Telnet out, SSH out, TCP port, or UDP port.