17: Command Reference
EMG™ Edge Management Gateway User Guide 458
Description
Sets the acceptable range for the internal temperature sensor (an SNMP trap is sent if the
temperature is outside of this range). Temperatures can be entered in either Celsius or
Fahrenheit; to indicate a temperature is Fahrenheit, append the degrees with an ‘F’, i.e., “75F”.
Parameter
set temperature <one or more parameters>
Parameters: low <Low Temperature in C. or F.>
high <High Temperature in C. or F.>
calibrate <Temperature Calibration in C. or F.|cancel>
Note: The calibration offset will be applied one hour after setting the value.
Description
Displays the acceptable range and the current reading from the internal temperature sensor.
show temperature
Syntax
show temperature
Description
Shows the temperature.
Xmodem Commands
set xmodem repo
Syntax
set xmodem repo import <Xmodem File> via <ftp|sftp|scp>
host <IP Address or Name> login <User Login>
[path <Path to Xmodem File>]
set xmodem repo rename <Xmodem File> newfile <New Filename>
set xmodem repo delete <Xmodem File>
Description
Manages a repository of files that can be sent to or received from a device port with Xmodem,
Ymodem, or Zmodem. The maximum file size is 20 MB, and the maximum total repository size is
25 MB.

Table of Contents

Other manuals for Lantronix EMG Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lantronix EMG Series and is the answer not in the manual?

Lantronix EMG Series Specifications

General IconGeneral
BrandLantronix
ModelEMG Series
CategoryGateway
LanguageEnglish

Related product manuals