15: Maintenance
EMG™ Edge Management Gateway User Guide 337
2. Enter the following:
Internal Temperature
Site Information
EMG Firmware
Note: The non-active boot bank is updated during the firmware update, without requiring
a reboot. The configuration on the current boot bank may optionally be copied to the non-
active boot bank during the firmware update.
Reboot Select this option to reboot the EMG immediately. The default is No.
Shutdown Select this option to shut down the EMG unit. The default is No.
Current Displays current temperature.
Low Sets the acceptable minimum for the internal temperature of the EMG. If the
temperature changes to be outside of this range, the EMG will issue an SNMP
trap.
High Sets the acceptable maximum for the internal temperature of the EMG unit. If the
temperature changes to be outside of this range, the EMG unit will issue an
SNMP trap.
Calibrate Offset An offset for calibrating the internal temperature of the EMG unit. The offset will be
applied one hour after setting the calibration value. Zeroing the offset will take
effect immediately and will cancel any current and/or pending calibration.
Data Center Rack Row Set these fields to define the rack row the EMG unit is located within a large data
center. The default for these fields is 1.
Data Center Rack
Cluster
Set these fields to define the rack cluster the EMG is located within a large data
center. The default for these fields is 1.
Data Center Rack Set these fields to define the rack the EMG unit is located within a large data
center. The default for these fields is 1.
Site Tag Tag or description used to identify the location or some other attribute of the EMG.
Current Version Displays the current firmware version.
Clear FW Update Log
(checkbox)
Clears the contents of the Firmware Update log file.
Firmware Update Log
(link)
To view a log of all prior firmware updates, click the Firmware Update Log link.
Update Firmware
To update the EMG firmware, select the checkbox. If you select this option, the
EMG unit reboots after you apply the update. The first time boot for each bank
may take up to 5 minutes. Subsequent boot times will be approximately 2
minutes.
To view a log of all prior firmware updates, click the Firmware Update Log
link.
Firmware Filename
The name of the firmware update file downloaded from the Lantronix web site.
Key
A key for validating the firmware file. The key is provided with the firmware file
(32 hex characters).

Table of Contents

Other manuals for Lantronix EMG Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lantronix EMG Series and is the answer not in the manual?

Lantronix EMG Series Specifications

General IconGeneral
BrandLantronix
ModelEMG Series
CategoryGateway
LanguageEnglish

Related product manuals