10: Device Ports
EMGâ„¢ Edge Management Gateway User Guide 226
3. Click the Add Site button.
To view or update a site:
1. In the Sites table, select the site and click the View Site button. The site attributes are
displayed in the bottom half of the page.
2. Update any of the site attributes.
3. Click the Edit Site button.
To delete a site:
1. Select the site in the Sites table.
2. Click the Delete Site button.
Site Commands
Go to Site Commands to view CLI commands which correspond to the web page entries described
above.
Dial-back Number The phone number to dial on callback for text or PPP dial-back connections. A
site must successfully authenticate, have Allow Dial-back enabled and have a
Dial-back Number defined in order for the site to be used for callback.
Allow Dial-back If enabled, the site is allowed to be used for dial-back connections.
Dial-back Delay For dial-back and CBCP Server, the number of seconds between the dial-in and
dial-out portions of the dialing sequence.
Dial-back Retries For dial-back and CBCP Server, the number of times the EMG unit will retry the
dial-out portion of the dialing sequence if the first attempt to dial-out fails.
Modem Timeout Timeout for dial-in and dial-on-demand PPP connections. Select Yes (default) for
the EMG to terminate the connection if no traffic is received during the configured
idle time. Enter a value of from 1 to 9999 seconds. The default is 30 seconds.
Restart Delay The number of seconds after the modem timeout and before the EMG unit
attempts another connection. The default is 30 seconds.
CBCP Server
Allow No Callback
For a CBCP Server site, allows "No Callback" as an option in the CBCP
handshake in addition to User-defined Number and Admin-defined Number.
Enable NAT Select to enable Network Address Translation (NAT) for PPP connections.
Note: IP forwarding must be enabled on Network Port Settings (on page 80) for
NAT to work.

Table of Contents

Other manuals for Lantronix EMG Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lantronix EMG Series and is the answer not in the manual?

Lantronix EMG Series Specifications

General IconGeneral
BrandLantronix
ModelEMG Series
CategoryGateway
LanguageEnglish

Related product manuals