13: Connections
EMG™ Edge Management Gateway User Guide 285
3. To save, click the Apply button.
To view, update, or disconnect a current connection:
The bottom of the Devices > Connections page displays current connections.
Figure 13-7 Current Connections
1. To view details about a connection, hold the mouse over the arrow in the Flow column.
2. To disconnect (delete) a connection, select the connection in the Select column and click the
Terminate button.
3. To reestablish the connection, create the connection again in the top part of the page.
4. To view information about Web connections, click the here link in the text above the table. The
Maintenance > Firmware & Configurations page displays.
Connection Commands
Go to Connection Commands to view CLI commands which correspond to the web page entries
described above.
Port If the to field is set to Device Port or Modem on Device Port, enter the number of the
device port. For all other options, this is the TCP/UDP port number, which is optional for
Telnet out and SSH out, but required for TCP Port and UDP Port.
Note: If you select Device Port, it must not have command line interface logins
enabled or be running a loopback test. To view the device port's settings, click the
Settings link to the right of the port number.
SSH Out
Options
Select one of the following optional flags to use for the SSH connection.
User: Login ID to use for authenticating on the remote host.
Version: Version of SSH. Select 1 or 2.
Command: Enter a specific command on the remote host (for example, reboot).
Trigger Select the condition that will trigger a connection. Options include:
Connect now: Connects immediately, or if you reboot the EMG, immediately on
reboot.
Connect at date/time: Connects at a specified date and time. Use the drop-down
lists to complete the date and time. Upon rebooting, the EMG unit reestablishes the
connection if the date/time has passed.
Auto-connect on characters transferring: Select the arrow indicating the direction
of the data transfer and either the minimum number of characters or a specific
character sequence that will trigger the connection.
You can select the direction of the data transfer only if Data Flow is bidirectional. Upon
rebooting, the EMG does not reestablish the connection until the specified data has
passed through one of the endpoints of the connection.

Table of Contents

Other manuals for Lantronix EMG Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lantronix EMG Series and is the answer not in the manual?

Lantronix EMG Series Specifications

General IconGeneral
BrandLantronix
ModelEMG Series
CategoryGateway
LanguageEnglish

Related product manuals