17: Command Reference
EMG™ Edge Management Gateway User Guide 448
Description
To display the overall status of all EMG units. Optionally emails the displayed information.
System Log Commands
show syslog
Syntax
show syslog [<parameters>]
Parameters
[email <Email Address>]
level <error|warning|info|debug>
log <all|netlog|servlog|authlog|devlog|diaglog|genlog>
display <head|tail> [numlines <Number of Lines>]
starttime <MMDDYYhhmm[ss]>
endtime <MMDDYYhhmm[ss]>
Description
Displays the system logs containing information and error messages.
Note: The level, display, and time parameters cannot be used simultaneously.
show syslog clear
Syntax
show syslog clear <all|netlog|servlog|authlog|devlog|diaglog|genlog>
Description
Clears one or all of the system logs.
USB Access Commands
set usb access
Syntax
set usb access <enable|disable>
Description
Enables or disables access to USB devices.