17: Command Reference
EMG™ Edge Management Gateway User Guide 395
set cflow connection
Syntax
set cflow connection <cloud|onpremise> [<one or more parameters>]
Parameters
host <IP Address or Name>
port <TCP Port>
secureport <enable|disable>
validatecerts <enable|disable>
mqttstate <enable|disable>
mqtthost <IP Address or Name>
mqttport <TCP Port>
mqttsecurity <enable|disable>
projecttag <Project Tag>
Description
Configure ConsoleFlow Cloud or On-Premise settings.
set cflow devicename
Syntax
set cflow devicename <Device Name> description <Device Description>
Description
Configure the device name and description used for registration.
set cflow timeoutcli
Syntax
set cflow timeoutcli <1-1800 seconds>
set cflow timeoutdp <1-1800 seconds>
Description
Configure the timeout for the ConsoleFlow Web Terminal sessions.
set cflow digitalprobe
Syntax
set cflow digitalprobe <Device Port # or List or Name>
frequency <disable|15-3600 seconds>
Description
Configures the device port digital probe for determining managed device connection status.