EasyManuals Logo
Home>Lantronix>Gateway>EMG Series

Lantronix EMG Series User Manual

Lantronix EMG Series
482 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #395 background imageLoading...
Page #395 background image
17: Command Reference
EMGâ„¢ Edge Management Gateway User Guide 395
set cflow connection
Syntax
set cflow connection <cloud|onpremise> [<one or more parameters>]
Parameters
host <IP Address or Name>
port <TCP Port>
secureport <enable|disable>
validatecerts <enable|disable>
mqttstate <enable|disable>
mqtthost <IP Address or Name>
mqttport <TCP Port>
mqttsecurity <enable|disable>
projecttag <Project Tag>
Description
Configure ConsoleFlow Cloud or On-Premise settings.
set cflow devicename
Syntax
set cflow devicename <Device Name> description <Device Description>
Description
Configure the device name and description used for registration.
set cflow timeoutcli
Syntax
set cflow timeoutcli <1-1800 seconds>
set cflow timeoutdp <1-1800 seconds>
Description
Configure the timeout for the ConsoleFlow Web Terminal sessions.
set cflow digitalprobe
Syntax
set cflow digitalprobe <Device Port # or List or Name>
frequency <disable|15-3600 seconds>
Description
Configures the device port digital probe for determining managed device connection status.

Table of Contents

Other manuals for Lantronix EMG Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lantronix EMG Series and is the answer not in the manual?

Lantronix EMG Series Specifications

General IconGeneral
BrandLantronix
ModelEMG Series
CategoryGateway
LanguageEnglish

Related product manuals