Error code Description Action
922.50 Fuser hot roll failed to reach target departure.
Fuser page count has exceeded life. Replace the
fuser unit assembly.
Go to
“Fuser unit assembly removal” on
page 331.
922.52 The fuser hot roll does not reach the “beginning
lamp detection” parameter in the specified time.
Fuser page count has exceeded life. Replace the
fuser unit assembly.
922.53 The fuser hot roll does not reach the “final lamp
detection” parameter, but not in the specified time.
Fuser page count has exceeded life. Replace the
fuser unit assembly.
922.54 The fuser hot roll has timed out and not reached
the “final lamp detection” parameter during the
specified time.
Fuser page count has exceeded life. Replace the
fuser unit assembly.
922.56 The fuser hot roll did not reach operating
temperature within new enhanced control.
Fuser page count has exceeded life. Replace the
fuser unit assembly.
922.57 The fuser hot roll did not reach operating
temperature after increasing interpage gap.
Fuser page count has exceeded life. Replace the
fuser unit assembly.
4062
Diagnostic information
201