3 Remove the three screws (A) securing the HCIT controller card assembly.
A
4 Remove the HCIT controller card assembly and the shield.
High capacity input tray (HCIT) media size actuator assembly removal
Note: Carefully remove the base machine from the HCIT tray assembly before proceeding.
1 Remove the HCIT controller card assembly. Go to “High capacity input tray (HCIT) controller card assembly
removal” on page 383.
2 Disconnect the two springs (A) from the frame.
Note: Leave the springs (A) attached to the cam size sensing plate (B) and the actuator switch (C).
4062
Repair information
384