Bin near full
3 Manually actuate each sensor to make it toggle between Open and Closed. If the sensor does not toggle,
then it is malfunctioning.
4 Press the Back or Sleep button to exit the test.
BASE SENSOR TEST
This test determines whether the following sensors inside the printer are working properly.
Toner level sensor
Narrow media sensor
Input sensor
Output (exit) sensor
Front door sensor
CAUTION—SHOCK HAZARD: Do not use your hand to toggle these switches. Use a nonconducting
item.
1 From the Diagnostics menu, select BASE SENSOR TEST.
2 Select a sensor.
3 Manually actuate the sensor to make it toggle between Open and Closed. If the sensor does not toggle,
then it is malfunctioning.
Note: Remove and then reinstall the toner cartridge to actuate the toner level sensor.
4 Press the Stop button to exit the test.
DEVICE TESTS
Quick Disk Test
Note: This is applicable only to model T656.
This test performs a non-destructive read/write test on one block per track on the disk. If the block is good,
then the saved data is written back to the disk.
1 From the Diagnostics menu, navigate to DEVICE TESTS > Quick Disk Test.
After the testing is completed, a message indicating whether the test passed or failed appears on the display.
2 Press the Stop button to return to DEVICE TESTS.