EasyManua.ls Logo

Mazda RX-8 2004 - Secondary Shutter Valve (Ssv) Actuator Construction;Operation; Secondary Shutter Valve (Ssv) Actuator Function; Variable Fresh Air Duct (Vfad) Actuator Function (13 B-Msp (High Power)); Variable Fresh Air Duct (Vfad) Solenoid Valve Construction;Operation (13 B-Msp (High Power))

Mazda RX-8 2004
540 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
INTAKE-AIR SYSTEM
011312
SECONDARY SHUTTER VALVE (SSV) ACTUATOR FUNCTION
CHU011320130S01
Opens and closes the SSV.
End Of Sie
SECONDARY SHUTTER VALVE (SSV) ACTUATOR CONSTRUCTION/OPERATION
CHU011320130S02
A diaphragm design has been adopted.
Normally, the rod is pushed by the force of the spring, closing the SSV. When intake manifold vacuum is
applied to the diaphragm chamber, the rod is pulled, opening the SSV.
End Of Sie
VARIABLE FRESH AIR DUCT (VFAD) SOLENOID VALVE FUNCTION (13B-MSP (HIGH POWER))
CHU011318740S03
Switches pressure (intake manifold vacuum or BARO) applied to the VFAD actuator according to a signal from
the PCM.
End Of Sie
VARIABLE FRESH AIR DUCT (VFAD) SOLENOID VALVE CONSTRUCTION/OPERATION (13B-MSP (HIGH
POWER))
CHU011318740S04
Composed of a solenoid coil, spring, plunger, and filter.
Energized
When the solenoid coil is energized, the plunger is pulled back. Pulling the plunger back opens the
passage between ports A and B. Due to this, BARO is applied to the actuator.
De-energized
Passage of port A is closed by the reaction force of the spring, and the passage between ports B and C is
opened. Due to this, intake manifold vacuum is applied to the actuator.
End Of Sie
VARIABLE FRESH AIR DUCT (VFAD) ACTUATOR FUNCTION (13B-MSP (HIGH POWER))
CHU011320130S03
Opens and closes the VFAD valve.
End Of Sie
OPEN
CLOSE
PUSH
PULL
BAROMETRIC
PRESSURE
VACUUM
SSV ACTUATOR
SSV VALVE
(ILLUSTRATION SHOWS
13B-MSP (HIGH POWER))
CHU0113S018
B
C
A
CHU0113S019

Table of Contents