In the Admin Menu > Loudspeaker and Microphone dialog, you can individually
configure and test both the microphone and the speaker (Test button). Set the cor-
responding checkboxes to activate/deactivate the devices. These settings will affect
all other camera settings that are using the audio functionality of the MOBOTIX
camera.
You can set the microphone either to
Low
,
Medium
or to
High sensitivity.
The
speaker volume can be controlled in a similar way. To play back sound over the
camera speaker at a low volume, choose a value of
–18
, for normal indoor volume,
choose
6
.
© MOBOTIX AG • Security-Vision-Systems • Made in Germany
www.mobotix.com • sales@mobotix.com • 10.10.2006
103/288
Software Camera Manual Part 2
Set the microphone to be
displayed on the level
meter
The microphone can be
deactivated irreversibly
Note
The microphone can react to noise or sounds in the vicinity of the
camera (provided the Microphone (MI) event has been activated in
the Event Settings). You may set the trigger value that triggers an
event, and also set the minimum duration the trigger level has to be
surpassed before the camera triggers. See section 7.6.1,
Event
Selection
, for more information on this topic.
Hint: Open Setup Menu > Display and Text Settings, set the Level
Meter to
Bar
, select
Microphone
as Level Meter Data, then click on
Set. The level meter that is now displayed in the live image of the
camera helps to determine the best possible trigger level for your
application.
This dialog also allows to permanently and irreversibly deactivate
the microphone (Admin Menu > Microphone and Loudspeaker >
More, then click on the disabled link and follow the instructions). You
will find additional information in this and the following dialogs.
The possibility to permanently and irreversibly deactivate the
microphone has been created for reasons of privacy protection and to
comply with the regulations of specific countries. It is not allowed in
some countries, for example, to install surveillance devices that can
record or transmit sound (e.g. in Germany when monitoring
workplaces).
Warning: Make sure you understand that this deactivation is
permanent and cannot be reversed even by MOBOTIX engineers!