Function Code Table NICE1000
new
User Manual
- 88 -
Function
Code
Parameter Name Setting Range Default Unit
Property
F5-21 X21 function selection
45: Light-load signal
46: Single/Double door
selection
47: Fire emergency oor
switchover signal
48: Virtual oor input
49: Fireghter switch signal
50: Brake travel switch
feedback signal 1
51–99: Reserved
(End)
00 -
F5-22 X22 function selection 00 -
F5-23 X23 function selection 00 -
F5-24 X24 function selection 00 -
F5-25
X25 higher-voltage
input function selection
00–99
01 -
F5-26
X26 higher-voltage
input function selection
02 -
F5-27
X27 higher-voltage
input function selection
03 -
F5-28
Terminal state display
1
- - -
F5-29
Terminal state display
2
- - -
F5-30
Floor I/O terminal state
display 1
- - -
F5-31
Floor I/O button state
display 2
- - -
Group F6: Basic Elevator Parameters
F6-00 Top oor of the elevator F6-01 to 16 5 -
F6-01
Bottom oor of the
elevator
1 to F6-00 1 -
F6-02 Parking oor F6-01 to F6-00 1 -
F6-03 Fire emergency oor 1 F6-01 to F6-00 1 -
F6-04 Elevator lock oor F6-01 to F6-00 1 -
F6-05 Service oors
0–65535
0: Not respond
1: Respond
65535 -
F6-06
Elevator function
control 1
0–65535 0 -
F6-07
Elevator function
control 2
0–65535 0 -
F6-08 Arrow blinking interval 0–5.0 1 -

Table of Contents