User Interface
4-46 Manual # 42-02-2P24
FIRE BYPASSES HOSPITAL?
Set to YES if Hospital Service is used for VIP, Priority or Commandeering Service. Set
this option to NO if Hospital Service is truly used for Hospital Service.
HIGH SPEED DELAY AFTER RUN?
Setting this option inserts a fixed delay (3 seconds) between the completion of a run
and the initiation of the next run. Use in applications in which an immediate “stop/
start” is undesirable. Under most circumstances, the initiation of a run is delayed by
the time required for door operation. In some cases, however, the car may stop and
start immediately in the absence of a door operation. For example, a direction reversal
upon being assigned a hall call while the car was parking.
SINGLE SPEED AC OPTION
Setting this option allows the direction output to clear once the car “steps” into the
floor. Typically the direction output is not cleared until the car enters the door zone.
However, for applications only requiring one speed, the direction must be cleared
prior to door zone to allow the car to arrive at the landing properly.
SABBATH OPERATION
If you do not have Sabbath Operation, set this option to NO by pressing the S push but-
ton, then press the N push button to exit.
If you have Sabbath Operation, set this option to YES by pressing the S push button.
Press the N push button to continue. The following will appear:
“FRONT UP STOP AT FLOOR 1?”
If you want the car to service this floor while traveling or initiating travel in the UP
direction, press S to select YES. (Pressing S again will set back to NO.)
Press + to increment floor value to the next landing. Continue until all desired front UP
stops are set to YES.
Press N to proceed to the next eligibility map. If there are no walk through doors on
this controller, rear eligibility maps will not display. In order, the next eligibility maps
are:
“REAR UP STOP AT FLOOR 1?”
“FRONT DOWN STOP AT FLOOR 2?”
“REAR DOWN STOP AT FLOOR 2?”
Remember that the + push button increments the floor value to the next landing and
that the N push button displays the next eligibility map.
LEVELING SENSOR ENABLED/DISABLED
Factory set to Enabled. Cannot be set.
•KCE DISABLED?
If set to Yes, keyboard command entry is disabled.
•ANALOG LOAD WEIGHER?
Enables analog load weigher logic and selects the type of learn operation to be per-
formed depending on the type of load weigher installed.
IND. BYPASSES SECURITY? YES / NO
Determines if Elevator Security is bypassed when the car is on Independent Service or
Test operation (available only when Security is enabled).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Motion Control Engineering Motion 4000 and is the answer not in the manual?

Motion Control Engineering Motion 4000 Specifications

General IconGeneral
BrandMotion Control Engineering
ModelMotion 4000
CategoryController
LanguageEnglish

Related product manuals