EasyManua.ls Logo

Motion Control Engineering Motion 4000

Motion Control Engineering Motion 4000
459 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix
A-8 Manual # 42-02-2P24
Accel Jerk out 0 Rate of decrease of acceleration to zero when
approaching contract elevator speed
ft/s
3
0 - 8.0 8.0
Decel Jerk in 0 Rate of increase of deceleration, up to Decel
Rate, when decreasing elevator speed
ft/s
3
0 - 8.0 8.0
Decel Jerk out 0 Rate of decrease of deceleration to zero when
slowing the elevator to leveling speed
ft/s
3
0 - 8.0 8.0
Accel Rate 1 Acceleration rate #1
ft/s
2
0 - 7.99 3.00
Decel Rate 1 Deceleration rate #1
ft/s
2
0 - 7.99 3.00
Accel Jerk in 1 Rate of increase of acceleration, up to ACCEL
Rate, when increasing elevator speed
ft/s
3
0 - 8.0 8.0
Accel Jerk out 1 Rate of decrease of acceleration to zero when
approaching contract elevator speed
ft/s
3
0 - 8.0 8.0
Decel Jerk in 1 Rate of increase of deceleration, up to Decel
Rate, when decreasing elevator speed
ft/s
3
0 - 8.0 8.0
Decel Jerk out 1 Rate of decrease of deceleration to zero when
slowing the elevator to leveling speed
ft/s
3
0 - 8.0 8.0
Accel Rate 2 Acceleration rate #2
ft/s
2
0 - 7.99 3.00
Decel Rate 2 Deceleration rate #2
ft/s
2
0 - 7.99 3.00
Accel Jerk in 2 Rate of increase of acceleration, up to ACCEL
Rate, when increasing elevator speed
ft/s
3
0 - 8.0 8.0
Accel Jerk out 2 Rate of decrease of acceleration to zero when
approaching contract elevator speed
ft/s
3
0 - 8.0 8.0
Decel Jerk in 2 Rate of increase of deceleration, up to Decel
Rate, when decreasing elevator speed
ft/s
3
0 - 8.0 8.0
Decel Jerk out 2 Rate of decrease of deceleration to zero when
slowing the elevator to leveling speed
ft/s
3
0 - 8.0 8.0
Accel Rate 3 Acceleration rate #3
ft/s
2
0 - 7.99 3.00
Decel Rate 3 Deceleration rate #3
ft/s
2
0 - 7.99 3.00
Accel Jerk in 3 Rate of increase of acceleration, up to ACCEL
Rate, when increasing elevator speed
ft/s
3
0 - 8.0 8.0
Accel Jerk out 3 Rate of decrease of acceleration to zero when
approaching contract elevator speed
ft/s
3
0 - 8.0 8.0
Decel Jerk in 3 Rate of increase of deceleration, up to Decel
Rate, when decreasing elevator speed
ft/s
3
0 - 8.0 8.0
Decel Jerk out 3 Rate of decrease of deceleration to zero when
slowing the elevator to leveling speed
ft/s
3
0 - 8.0 8.0
A3 Multistep Ref
Speed Command 1 Multi-Step Speed command #1 ft/m 0
Speed Command 2 Multi-Step Speed command #2 ft/m 0
Speed Command 3 Multi-Step Speed command #3 ft/m 0
Speed Command 4 Multi-Step Speed command #4 ft/m 0
Speed Command 5 Multi-Step Speed command #5 ft/m 0
Speed Command 6 Multi-Step Speed command #6 ft/m 0
Speed Command 7 Multi-Step Speed command #7 ft/m 0
Speed Command 8 Multi-Step Speed command #8 ft/m 0
Table A.2 Magnetek AC Drive Table
#
Operator
Display
Parameter Description Unit
Setting
Range
MCE
Defaults
Field Set

Table of Contents

Related product manuals