F7 Settings Record
A-17
A
Motion 4000
106
DETS Delta Distance: Distance in Inches on
either side of the down emergency terminal
switch position inside which the car must
detect the down emergency terminal switch. If
not, the car will perform an emergency stop.
107
DETS Delta Speed: Delta speed is generally
unused in applications below 400 FPM. Delta
Speed provides an “adder” to DETS speed.
DETS speed and Delta speed together may not
exceed 95% of contract speed. If you are trip-
ping an ETS fault during car setup, you can
choose to use this adder or you can choose to
temporarily disable the ETS switches by set-
ting them to Unused until you have sufficient
control of the car.
108
DNTS1 Speed: Speed in feet per minute which
the car must be below when tripping the
DNTS1 switch.
109
DNTS1 Distance: Distance in inches from the
bottom terminal floor level position at which a
virtual DNTS1 switch is positioned.
110
DNTS1 Delta Distance: Distance in inches on
either side of the DNTS1 switch inside which
the car must detect the switch. If not, the car
will perform an emergency slow down.
111
DNTS1 Delta Low Speed: Along with the Delta
High Speed setting, determines a speed range
which the car must be within to avoid causing
an emergency slow down.
112
DNTS1 Delta High Speed: Along with the Delta
Low Speed setting, determines a speed range
which the car must be within to avoid causing
an emergency slow down.
113 DNTS2 Speed (See DNTS1)
114 DNTS2 Distance (See DNTS1)
115 DNTS2 Delta Distance (See DNTS1)
116 DNTS2 Delta Low Speed (See DNTS1)
117 DNTS2 Delta High Speed (See DNTS1)
118 DNTS3 Speed (See DNTS1)
119 DNTS3 Distance (See DNTS1)
120 DNTS3 Delta Distance (See DNTS1)
121 DNTS3 Delta Low Speed (See DNTS1)
122 DNTS3 Delta High Speed (See DNTS1)
123 DNTS4 Speed (See DNTS1)
124 DNTS4 Distance (See DNTS1)
125 DNTS4 Delta Distance (See DNTS1)
Table A.3 F7 Parameter Log
ID# Description Setting

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Motion Control Engineering Motion 4000 and is the answer not in the manual?

Motion Control Engineering Motion 4000 Specifications

General IconGeneral
BrandMotion Control Engineering
ModelMotion 4000
CategoryController
LanguageEnglish

Related product manuals