Program 90 : Maintenance Program
90-10 : System Alarm Setup
Aspila EX Software Manual Programming 1039
5 0 0 Download Error Download may have failed
because the PCB is blocked
(disabled) or the sub-pro-
gram does not exist on the
system flash card.
After unblocking the PCB, if
RECover message is received
in the alarm report, it is cor-
rected. If not, then replace the
system flash card.
6 0 0 -- Not Used --
7 1 (MAJ) 0 Power Failure System power supply may
be defective or commercial
power is off.
Check the system AC switch,
fuse and AC outlet. If still faulty,
replace the power supply.
8 1 (MAJ) 0 RAM Backup Battery
Error
RAM backup battery on the
CPRU PCB is unplugged or
defective.
Check the battery connector. If
it is connected correctly, then
replace the battery.
9 0 0 Blocking (No default
setting)
Failure may have occurred
because:
Terminal blocking
detected.
Terminal is unplugged.
Wire is disconnected.
DSTU card is defective.
Check the terminal wiring and
reconnect properly. Then
unplug and plug in the PCB. If
RECover message is received
in the alarm report, it is correct.
If not, replace the PCB and/or
terminal.
10 0 0 ISDN
11 0 0 CTI
12 0 0 ACD
13 0 0 -- Not Used --
:: : :
30 2 (MIN) 0 SMDR Buffer Full The SMDR buffer is full. Check the printer for the
SMDR.
31 0 0
:: : :
35 0 0 CS Blocking
36 0 0 CS Error Information 1
37 0 0 CS Transmission Error
38 0 0 CSIU Dch Error
39 0 0 CSIU Transmission
Error
40 0 0 CS Error Information 2
41 0 0
:: :